SCUBA: Self-Contained Underwater Breathing Apparatus. The very definition of the acronym underlines the importance of testing the air that goes into the cylinder. When at depth, the very quality of the air you breathe is everything. Safety Lab Plus tests to all major diving industry standards, including CGA, PADI, ANDI, and Nitrox, and provides your customers the confidence to keep their focus where it should be: the beauty of the underwater world.
For more infoanalytes / standard | CGA e | Nitrox i | Nitrox ii | *oca | navsea | z-275 |
---|---|---|---|---|---|---|
Oxygen (%) | 20 - 22 | 31 - 33 | 35 - 37 | 20 - 22 | 20 - 22 | 20 - 22 |
Nitrogen (%) | ------ | ------ | ------ | ------ | ------ | 78 - 80 |
Carbon Dioxide (ppm) | 1000 | 1000 | 1000 | 1000 | 1000 | 600 |
Carbon Monoxide (ppm) | 10 | 10 | 10 | 2 | 10 | 3 |
THC as Methane (ppm) | 25 | 25 | 25 | 25 | 25 | 10 |
VOC as Non-methane Equivalent (ppm) | ------ | ------ | ------ | ------ | ------ | 5 |
Nitrous Oxide (ppm) | ------ | ------ | ------ | ------ | ------ | ------ |
Nitrogen Dioxide (ppm) | ------ | ------ | ------ | ------ | ------ | ------ |
Nitric Oxide (ppm) | ------ | ------ | ------ | ------ | ------ | ------ |
Sulfur Dioxide (ppm) | ------ | ------ | ------ | ------ | ------ | ------ |
Halogenated Solvents (ppm) | ------ | ------ | ------ | ------ | ------ | ------ |
Halogenated Hydrocarbons (ppm) | ------ | ------ | ------ | ------ | ------ | 5 |
H2O / Dew Point (ppm/degree) | 67 / -50°F | 67 / -50°F | 67 / -50°F | 67 / -50°F | 24 / -65°F | 27 / -53°C |
Oil & Particles (mg/m3) | 5 | 5 | 5 | 0.1 / 0.1 | 5 | 1 |
Unknowns | ------ | ------ | ------ | ------ | ------ | ------ |
Odor | None | None | None | None | None | None |
*Oil and particles are analyzed and reported separatly